  1 look inside for: field metrology wells infrared calibrators handheld and field dry-wells micro-baths environmental monitoring thermometer readouts reference sensors industrial temperature calibration selection guide tools for industrial instrumentation and calibration technicians t emperature measurement and calibration
64% 253 inh o 275 inh o legend rtd calibration dial thermometer calibration temperature transmitter, switch, and controller loop calibration infrared thermometer and thermal imager calibration monitoring temperature and humidity 2 selection guide
3 field metrology wells new! precision infrared calibrators handheld dry-wells model 9142/9142p page 4 9143/9143p page 4 9144/9144p page 4 4180 page 6 4181 page 6 9100s page 8 9102s page 8 range C25 c to 150 c 4-20 ma 33 c to 350 c 4-20 ma 50 c to 660 c 4-20 ma C15 c to 120 c 35 c to 500 c 35 c to 375 c C10 c to 122 c best accuracy 0.2 c ?0.2 c 0.35 c ?0.35?c ?0.35?c 0.25 c 0.25 c applications field dry-wells sensors model 9009 page 9 9103 page 10 9140 page 10 9141 page 10 9150 page 10 prt page 15 thermistor page 15 range(s) C15 c to 350 c C25 c to 140 c 35 c to 350 c 50 c to 650 c 150?c to 1200?c C200?c to 670?c 0?c to 100?c best accuracy 0.2 c 0.25 c 0.5 c 0.5 c 5 c see pages 14C15 see pages 14C15 applications thermocouples micro baths thermometer readouts and environmental monitoring model 6102 page 11 7102 page 11 7103 page 11 1551a/1552a page 13 1523/1524 page 13 1529 page 14 1620a page 12 range 35 c to 200 c C5 c to 125 c C30 c to 125 c C200 c to 300 c C200 c to 2315 c C200 c to 962 c 15?c to 35?c 20 %rh to 70 %rh best accuracy 0.25 c 0.25 c 0.25 c 0.05 c 0.015 c ?0.006?c ?0.25?c ?2?%rh channels n/a n/a n/a n/a 1 or 2 4 2 applications legend rtd calibration dial thermometer calibration temperature transmitter, switch, and controller loop calibration infrared thermometer and thermal imager calibration monitoring temperature and humidity selection guide www.flukecal.com
fluke calibration 9142, 9143, 9144 field metrology wells ? lightweight, portable, and fast ? cool to C25 c in 15 minutes and heat to 660 c in 15 minutes ? built-in two-channel readout for prt, rtd, thermocouple, 4-20 ma current ? true reference thermometry with accuracy to ?0.01?c ? specifications guaranteed in an ambient range of 13 c to 33 c ? on-board automation and documentation ? metrology performance in accuracy, stability, uniformity, and loading field metrology wells offer accuracy, portability, and speed for nearly all field calibration applications. these units are packed with func - tionality and are remarkably easy to use. field metrology wells are light weight, small, and quick to reach temperature set points, yet also stable, uniform, and precise. this industrial product line is perfect for transmitter loop, comparison calibration, or a simple check of a ther - mocouple sensor. there is no need to have to carry additional tools into the field as the process option offers a built-in readout for resis - tance, voltage, and ma measurement, 24v loop power, and on-board documentation. typical applications: ? loop calibration of temperature transmitters ? thermocouple calibration or verification ? calibrations of rtds or prts ? testing of thermostatic switches ? verification of industrial thermometers each unit includes: accredited report of calibration, insert, insert removal tool, power cord, user manual, 9930 interface -it software, serial cable, test leads (process versions only), spare prt connector (process version only) recommended accessories: carrying case, met/temp ii automated calibration software, reference temperature sensor ordering information 9142-x field metrology well, C25 c to 150 c 9142-x-p field metrology well, process version, C25 c to 150 c 9143-x field metrology well, 33 c to 350 c 9143-x-p field metrology well, process version, 33 c to 350 c 9144-x field metrology well, 50 c to 660 c 9144-x-p field metrology well, process version, 50 c to 660 c 9142-case case, carrying, field metrology wells 5616-12-a prt 305 mm x 6.35 mm (11.75 in x 1/4 in) w/ nist traceable calibration, C200?c to 420?c 5609-12-a prt 305 mm x 6.35 mm (11.75 in x 1/4 in) uncalibrated, C200?c to 660?c 1923-4-7 calibration, prt C200?c to 660?c x = insert (interchangeable). specify a, b, c, d, e, or f 4 field metrology wells
9142 insert options 9143/9144 insert options summary specifications for 9142, 9143, and 9144 model 9142/9142-p 9143/9143-p 9144/9144-p range C25 c to 150 c 33 c to 350 c 50 c to 660 c display accuracy 0.2 c 0.2 c 0.35 c (420 c) 0.5c (660 c) stability 0.01 c 0.02 c (33 c) 0.03 c (350 c) 0.03 c (50 c) 0.05 c (660 c) heating time (max) 23 min 5 min 15 min cooling time 15 min to C25 c 14 min to 100 c 25 min to 100 c weight 8.2 kg (18 lbs) 7.3 kg (16 lbs) 7.7 kg (17 lbs) process version accuracy 0.01 c at C25 c 0.02 c at 155 c 0.02 c at 50 c 0.04 c at 350 c 0.02 c at 50 c 0.07 c at 660 c rtd inputs (process version) 2-, 3-, 4-wire rtd. resistance range of 0 to 400 ohms. ni-120, pt-100 (385), pt-100 (3926), pt-100 (jis), or ? tc inputs (process version) type j, k, t, e, r, s, b, l, u, n, c, and mv ma specs (process version) range: 0-24 ma with 24-28 vdc loop power ma accuracy: 0.02% of rdg + 0.002 ma 5 field metrology wells www.flukecal.com
fluke calibration 4180 and 4181 precision infrared calibrators accurate yet portable ? combined temperature range of C15 c to 500 c ? infrared display accuracy as good as ?0.35 c on both units ? convenient handle and weight of 9.5 kg (21 lbs) or less for portability easy to get dependable results ? each unit is given an accredited radiometric calibration for consistent, reliable, and traceable results ? corrections for emissivity are performed automatically with no manual calculations ? audio/visual stability indication provided for ease of use ? stores thermometer calibration routines including temperature set-points, calibration distance, emissivity setting, and use of external aperture a superior target ? 152 mm (6 in) diameter target addresses critical size-of-source effect issues for infrared thermometers and thermal imager calibration requirements ? stability as good as ?0.05 c over 30 minutes for both models ? uniformity as good as ?0.1 c over the inner 127 mm (5 in) diameter each unit includes: accredited radiometric report of calibration, protective target cover, manual, 9930 interface -it software recommended accessories: protective carrying case do you calibrate your infrared thermometers and thermal imagers? even those infrared thermometers that cannot be adjusted can benefit from a calibration that demonstrates the consistency and validity of your results. a trusted cali - bration means less worry, fewer questions and more time being productive. the 4180 series of precision infrared calibrators for infrared thermometers and thermal imagers is fast, accurate, and easy to use. it comes with an accredited calibration from one of the worlds most trusted temperature cali - bration laboratories, sample calibration procedures for fluke thermometers built right in, and everything you need to get started making high-quality infrared thermometer calibrations. this is the perfect solution for any infrared thermometer or thermal imager within its temperature range. ordering information 4180 precision infrared calibrator, C15 c to 120 c 4181 precision infrared calibrator, 35 c to 500 c 4180-case protective carrying case 4180-dcas protective carrying case with wheels precision infrared calibrators 6
why calibrate? business decisions costing thousands of dollars are based on the results of your measurements, so they had better be right! it can be very expensive to shut down a line for repairs and maintenance but it might be catastrophic if the shut down is unplanned. to stand by your recommendations with confidence, you should definitely have your thermometers calibrated. application notes for information on emissivity, size of source effect and radiometric calibration see the fluke calibration application note infrared temperature calibration 101 and have a look at our guide to infrared thermometer calibration to get started quickly with your new calibrator. you can download both docu - ments from our web site. summary specifications for 4180 and 4181 4180 4181 temperature range (@ 23c ambient and 0.95 emissivity) C15 c to 120 c 35 c to 500 c infrared display accuracy 0.40 c at C15 c 0.04 c at 0 c 0.55 c at 120 c 0.35 c at 35 c 0.70 c at 200 c 1.6 c at 500 c display resolution 0.01 target size 152 mm (6 in) dia. stability 0.1 c at C15 c 0.05 c at 0 c 0.1 c at 120 c 0.05 c at 35 c 0.2 c at 250 c 0.4 c at 500 c uniformity (5.0-inch diameter zone at the center of the target) 0.15 c at C15 c 0.1 c at 0 c 0.25 c at 120 c 0.1 c at 35 c 0.5 c at 250 c 1.0 c at 500 c heating time 15 min: C15 c to 120 c 14 min: 23 c to 120 c 20 min: 35 c to 500 c cooling time 15 min: 120 c to 23 c 20 min: 23 c to C15 c 100 min: 500 c to 35 c 40 min: 500 c to 100 c stabilization time 10 minutes 10 minutes excellent performance the 4180 reaches temperatures from C15?c to 120?c and the 4181 has a temperature range from 35?c to 500?c. check out the uniformity of the large six-inch targets shown in the thermal imager photo. the uniformity and stability are so good that variations cant be detected with a thermal imager. uniformity is important in infrared temperature calibration work because an infrared thermometer will see as much as the entire target when placed at the appropriate calibration distance and each pixel of a thermal imager registers a temperature that needs to be both accurate and consistent across the imager. 7 precision infrared calibrators www.flukecal.com
9100 fixed-block options fluke calibration 9100s and 9102s handheld dry-well temperature calibrators ? a temperature source that you can take anywhere ? fast and easy calibrations of temperature sensors ? 9100s model weighs only 2 lbs, 3 oz (1 kilogram) ? temperature ranges from C10 c to 375 c ? stability during calibrations to 0.05 c ? direct interface to the fluke 754 documenting process calibrator each unit includes rs-232 interface, instrument control software and a nist-traceable calibration. recommended accessories: carrying case, additional inserts, reference temperature sensor and indicator, battery pack temperature sensor calibration is easy with a handheld dry-well. easily connect a fluke 754 to a dry-well for a fully automated temperature calibration that includes the temperature transmitter and temperature sensor. ordering information 9100s handheld dry-well 9300 rugged carrying case, 9100 9102s handheld dry-well, comes with your choice of two 3102 inserts 9308 hard carrying case, 9102/9132 9320a battery pack, 115v (9102s run time: 4 hrs) 3102-1 insert, al 1/16 in (1.6 mm) 3102-2 insert, al 1/8 in (3.2 mm) 3102-3 insert, al 3/16 in (4.8 mm) 3102-4 insert, al 1/4 in (6.4 mm) (standard) 3102-6 insert, al 3/8 in (9.5 mm) (standard) 3102-7 insert, al 7/16 in (11.1 mm) (standard) 3102-8 insert, al 5/32 in (4 mm) (standard) 2514 dry-well interface cable to fluke 754 insert. specify a, b, d handheld dry-wells 754 documenting process calibra t or null modem dr y-well (3.5 mm) dr y-well (d b9) 2514 d r y-well interfac e cable 3.5 mm interfac e cable fluke calibration fluke calibration fluke calibration 8
9 fluke calibration 9009 industrial dual-block calibrator cut your calibration time in half ? calibrate temperature sensors fast ? independently controlled cold and hot blocks ? C15 c to 110 c (cold block), 50 c to 350 c (hot block) ? self-contained in a rugged watertight case ? four removable inserts, ? direct interface to fluke 754 each unit includes four removable inserts, including two with holes that are 6.4 mm (1/4 in) and two with holes that are 4.8 mm (3/16 in) in diameter. each unit also includes a power cord, insert removal tool, rs-232 interface, instrument control software and a nist-traceable calibration recommended accessories: additional inserts, reference temperature sensor and indicator tip: while youre checking your transmitter sensor at one temperature, the other well can be heating or cooling to your next set-point. system accuracy improvement achieved with a calibrated pt100 sensor. 1. 2 0.8 0.4 0 rss err or c standar d sensor calibr ated sensor s ystem accur acy impr oved by mor e than 75 %! why calibrate thermometers? because your performance will go up and your costs will come down. as suggested in the example in table 1, the cost of inac - curate measurements can be quite high. high cost of not calibrating a sensor process fluid water flow rate 100 gallons per minute control temp 38 f energy cost rate per kw-hr energy cost 70,812 (rate ) per year table 1. annual cost of energy due to a 1?c temperature error ordering information 9009-b dual block dry-well (black), C15?c to 350?c 9009-y dual block dry-well (yellow), C15 c to 350c 3102-1 insert 1.6 mm (1/16 in) 3102-2 insert 3.2 mm (1/8 in) 3102-3 insert 4.8 mm (3/16 in) 3102-4 insert 6.4 mm (1/4 in) 3102-5 insert 7.9 mm (5/16 in) 3102-6 insert 9.5 mm (3/8 in) 3102-7 insert 11.1 mm (7/16 in) 3102-8 insert 4 mm (5/32 in) 2514 dry-well interface cable to fluke 754 9 now its easy to work twice as fast. field dry-wells www.flukecal.com
10 insert ?a? insert ?b? insert ?c? insert ?d? 1/16 in (1.6 mm) 1 /2 in (12.7 mm) 1 /8 in (3.2 mm) 1/ 4 in (6.35 mm) 1/ 4 in (6.35 mm) 1/ 4 in (6.35 mm) 1/ 4 in (6.35 mm) 3 mm 3 mm 6 mm 6 mm 4 mm 4 mm 3/8 in (9.5 mm) 3/8 in (9.5 mm) 3/8 in (9.5 mm) 3/ 16 in (4.8 mm) 3/ 16 in (4.8 mm) 3/ 16 in (4.8 mm) 9103, 9140, 9141 and 9150 insert options fluke calibration 9103, 9140 and 9141 field dry-wells and 9150 thermocouple furnace temperature sensor test and calibration ? lightweight and very portable ? accuracy to ?0.25 c ? rs-232 and interface-it software included ? interchangeable inserts ? 9103 goes as low as C25 c. ? 9140 is 6 pounds (2.7 kg) and 9141 is 3.6 kg (8 pounds) ? 9140 and 9141 reach max temp in 12 minutes ? 9150 extends up to 1200 c covering a wide range of t/c types. ? direct interface to fluke 754 recommended accessories: carrying case, additional inserts, reference temperature sensor and indicator each dry-well includes one of four available well inserts, an optional carrying case, rs-232 interface, instrument control software and a nist-traceable calibration. fluke calibration dry-wells interface directly to the fluke 754 for fully automated calibration. ordering information 9103 dry-well, C25 c to 140 c 9140 dry-well, 35 c to 350 c 9141 dry-well, 50 c to 650 c 9150 thermocouple furnace, 150 c to 1200 c 9316 rugged carrying case for 9103 9308 rugged carrying case for 9140 9309 rugged carrying case for 9141 9315 rugged carrying case for 9150 2514 dry-well interface cable to fluke 744 insert (interchangeable). specify a, b, c, d 10 field dry-wells and furnaces
fluke calibration met/temp ii software easy-to-use temperature calibration automation software ? fully automated calibration of rtds, thermocouples, thermistors and many heat sources ? calibrates up to 100 sensors at up to 40 points ? performs coefficient calculations and generates tables and reports ? reports conform to ansi and ncsl standards each unit includes: cd, rs-232 multiplexer box, adapter, and pc cable fluke calibration log ware and log ware ii data logging and analysis software turns any fluke calibration thermometer readout into a real-time data logger ? calculates statistics and displays customized graphs ? user-selectable alarms, delayed start times, and sample intervals ? logging intervals from 1 second to 24 hours ? user-settable alarm functions ? choose logware ii for readouts with more than one channel 11 tip: for improved accuracy, use an external reference temperature indicator and sensor such as a 1521 and 5615-12-i combination. ordering information 7103 micro-bath, C30 c to 125 c (includes a transport seal lid and a 2085 test lid) 7102 micro-bath, C5 c to 125 c (includes a transport seal lid and a 2082-p test lid) 6102 micro-bath, 35 c to 200 c (includes a transport seal lid and a 2082-m test lid) 5010-l silicone oil, type 200.05, 1 liter (usable range: C40 c to 130 c) 5013-l silicone oil, type 200.20, 1 liter (usable range: 10 c to 230 c) 9317 carrying case for 7103 9310 carrying case for 6102 9311 carrying case for 7102 9934-m software, log ware, 1-channel, multi user 9934-s software, log ware , 1-channel, single user 9935 log ware ii, multiple channel logging software 9938 software, met/temp ii 2514 dry-well interface cable to fluke 754 * software requires windows ? 98 or higher 11 9103, 9140, 9141 and 9150 insert options see data logged in real-time. micro-baths www.flukecal.com fluke calibration 6102, 7102 and 7103 micro-baths portability and extreme stability ? temperature sensor calibration ? stability to 0.015 c ? ranges from C30 c to 200 c ? accepts oddly shaped sensors ? exceptional bath portability ? direct interface to fluke 754 each unit includes a stir bar, power cord, rs-232 interface, instrument control software and a nist-traceable calibration. recommended accessories: fluid, case, reference probe and meter, extra stir bar, tank extension for lig, met/temp ii
dewk 1620a high-accuracy thermo-hygrometer ? superior accuracy ? new! network enabled ? new! upgraded software ? powerful logging and analysis tools ? two interchangeable calibrated sensors ? huge memory now you can easily monitor and record conditions throughout your entire facility with the dewks new ethernet and wireless capabilities, and set your upgraded log ware iii software to notify you immediately of changing con - ditions. the 1620a accepts inputs from up to two sensors, which may be mounted directly on the unit or remotely (up to 100 feet away). each sensor comes with a nvlap-accredited calibration for temperature and relative humidity from fluke calibration, containing its own nist-traceable calibration data, so recalibration doesnt require the main unit. the 1620a-s reads temperature to ?0.25?c over its calibrated range of 15?c to 35?c. relative humidity readings are to 2 %?rh from 20?% rh to 70%?rh. recommended accessories: log ware iii software, protective case for spare sensor return for calibration 9936A log ware iii software ? remote monitoring and logging ? supports ethernet, rs-232, and wireless communications ? customizable graphs, alarms, email settings and statistics ? support for hot-swapping sensors ? exports data to html, rtf or ascii ? security features that include pass - words, groups, and customizable permissions if you really want to get the most out of your dewk, log ware iii is worth every penny. by adding fluke calibrations logware iii software, you can simultaneously monitor an unlimited number of dewk sensors. the windows-based software enables statistical and graphical analysis of real-time or previously recorded data, and can send emails to pdas, pagers, and cell phones when triggered by user-defined events. 1622a-s dewk thermo-hygrometer with log ware iii software and wireless kit 1621a-s dewk thermo-hygrometer with log ware iii software 1620a-s dewk thermo-hygrometer 9328 protective case for 1620a and two sensors 2607 protective case for one spare sensor 2626-s spare sensor 9936A log ware iii software 12 have everything you need at a glance with logware iii. environmental monitoring
ordering information 1551a-9 thermometer, fixed rtd, C50 c to 160 c, 4.8 mm x 229 mm (3/16 in x 9 in) 1551a-12 thermometer, fixed rtd, C50 c to 160 c (-58 f to 320 f), 6.35 mm x 305 mm (1/4 in x 12 in) 1552a-12 thermometer, fixed prt, C80 c to 300 c (-112 f to 572 f), 6.35 mm x 305 mm (1/4 in x 12 in) 1551a-case case, 1551-2, carrying note: append -dl to any mainframe to include datalogging 1523 thermometer readout, handheld, 1 channel 1524 thermometer readout, handheld, 2 channel, data logger 1523-cal 1523 accredited calibration 1524-cal 1524 accredited calibration 5610-9-p probe, precision thermistor, stainless steel, 0 c to 100 c, (1/8 in x 9 in) 5616-6-p probe, prt, 100 ohm, C200 c to 300 c, 4.8 mm x 152.4 mm (3/16 in x 6 in) 5609-12-p probe, prt, 100 ohm, C200 c to 660 c, 6.35 mm x 304.8 mm (1/4 in x 12 in) 5609-9bnd-p probe, prt, 25 ohm, 90 bend at 9 inches, C200 c to 660 c, 6.35 mm x 304.8 mm (1/4 in x 12 in), note: 5609 is not calibrated: (request 1924-4-7 calibration) 9935-s software, logware ii, single user 1523-case case, 1523/1524 readout and probe carrying fluketpak tpak , meter hanging kit 2373-lprt adapter, lemo to mini grabbers (4-wire) 2373-ltc adapter, lemo to universal tc (tc) 2384-p smart connector, prt (gray cap), spare 2384-t smart connector, tc (blue cap), spare 13 handheld thermometer readouts fluke calibration 1551a/1552a stik thermometers probe and digital readout combined into one unit ? accuracy of 0.05 c ( 0.09 f) over full range ? intrinsically safe (atex and iecex compliant) ? two models to choose from (C50 to 160 c or C80 to 300 c) ? optional data logging of up to 10,000 time-stamped measurements ? display temperature in c or f ? 300-hour battery life on three aaa batteries recommended accessories: 1551-case fluke calibration 1523/1524 reference thermometers measure, graph and record three sensor types with one tool ? measure rtds, prts, thermistors and thermocouples ? high accuracy: prts up to 0.011 c and thermocouples: up to 0.24 c ? 1523: single channel with memory for 25 readings ? 1524: two channels with datalogging of up to 15,000 time- and date-stamped measurements ? graphical temperature trend feature ? info-con connectors store probe parameters ? 20-hour battery life on three aa batteries recommended accessories: prt: 5609-9bnd-p (no cal incl.), thermistors: 5610-9-p, 2373-lprt lemo to mini-grabbers (4-wire), 2373-ltc lemo to universal tc adapter, 2384-p spare prt info-con connector, 2384-t spare tc info-con connector, 9935-s logware ii software (single user). www.flukecal.com summary specifications for 1551a, 1552a, 1523 and 1524 1551a 1552a 1523 1524 sensor types fixed thin-film rtd fixed wire-wound prt one input: rtds, prts, thermocou- ples and thermistors two inputs: rtds, prts, thermocou- ples & thermistors temperature range C50 c to 160 c (-58 f to 320 f) C80 c to 300 c (-112 f to 572 f) C200 c to 2315 c (-328 f to 4199 f) accuracy 0.05 c (combined probe and readout; full range) prt (readout only at 0 c): 0.015 c thermistor (readout only at 0 c): 0.002 c temperature resolution selectable: 0.1, 0.01, 0.001 prts and thermistors: 0.001 thermocouples: 0.01 operating range C10 c?to 50?c (14 f to 122 f) 13 c?to 33?c (55 f to 91 f) data logging 10,000 time-stamped readings to internal memory (optional) 25 readings w/stats 25 readings w/stats; 15,000 time and date stamped communications rs-232 stereo jack (access calibration parameters only) rs-232 (9940 i/o toolkit software included) size (hxwxd) 114 mm x 57 mm x 25 mm (4.5 in x 2.25 in x 1.0 in) 96 mm x 200 mm x 47 mm (3.75 in x 7.9 in x 1.86 in) weight 196 g (7 oz) 650 g (22 oz) calibration (included) nvlap-accredited nist-traceable (accredited available upon request)
ordering information 1529 chub-e4, 2 tc and 2 prt/ thermistor inputs 1529-r chub-e4, 4 prt/thermistor inputs 1529-t chub-e4, 4 tc inputs 2506-1529 ieee option 9322 rugged carrying case 5611t-l flexible teflon coated precision thermistor, 0 c to 100 c (32 f to 212 f) 5610-9-l precision thermistor, 0 c to 100 c (32 f to 212 f) 5626-12-l secondary prt, C200 c to 660 c (-328 f to 1220 f), 12.7 mm x 6.35 mm (12 in x 1/4 in) 5616-6-l probe, prt, 100 ohm, C200 c to 300 c (-328 f to 572 f), 4.8 mm x 152.4 mm (3/16 in x 6 in), (request calibration 1922-4-n) 5616-9-l probe, prt, 100 ohm, C200 c to 420 c (-328 f to 788 f), 4.8 mm x 152.4 mm (3/16 in x 6 in), (request calibration 1922-4-8) 5616-12-l secondary prt, C200 c to 420 c (-328 f to 788 f), 12.7 mm x 6.35 mm (12 in x 1/4 in) (nist-traceable cal included) l = mini-spade lead wire termination 9935 logware ii, multiple channel logging software 14 precision thermometer readout fluke calibration 1529 chub-e4 thermometer lab-quality accuracy on four channels ? four channels for prts, thermistors and thermocouples ? simultaneous measurement on four channels ? displays eight user-selected data fields ? logs up to 8,000 readings ? battery provides eight hours of continuous operation ? compatible with logware and met/temp ii software recommended accessories: prt (5626-12-l, 5615-12-l, or 5627a-12-l), thermistor (5611t-l or 5610-l), rugged carrying case (holds 1529 and four probes), logware ii multi-channel logging software (see page 11). summary specifications for 1529 prt/rtd, 1529 thermistor and 1529 thermocouple 1529 prt/rtd 1529 thermistor 1529 thermocouple inputs 2 channels prt/thermistor and 2 channels tc, or 4 channels prt/thermistor, or 4 channels tc, specify when ordering; prt/thermistor channels accept 2, 3, or 4 wires; tc inputs accept b, e, j, k, n, r, s, t, and au-pt tc types temperature range C189 c to 960 c (C308 f to 1760 f) C50 c to 150 c (C58 f to 302 f) C270 c to 1800 c (C454 f to 3272 f) measurement range 0 to 400 0 to 500 k C10 mv to 100 mv characterizations its-90, iec- 751(din385), callendar-van dusen steinhart-hart, ysi-400 nist monograph 175, 3-point deviation function applied to nist 175, 6th-order polynomial temperature accuracy, typical (meter only) 0.006 c at 0 c 0.009 c at 100 c 0.0025 c at 0 c 0.025 c at 100 c ext. rjc int. rjc k at 600 c t at 200 c 0.15 c 0.1 c 0.4 c 0.3 c temperature resolution 0.001 0.0001 0.01 to 0.001 operating range 16 c to 30 c (60.8 f to 86 f) logging intervals 0.1, 0.2, 0.5, 1, 2, 5, 10, 30, or 60 seconds; 2, 5, 10, 30, or 60 minutes communications rs-232, ieee-488 (gpib) optional size (hxwxd) 102 x 191 x 208 mm (4.0 x 7.5 x 8.2 in) weight 2 kg (4.5 lb) calibration accredited nist-traceable resistance calibration and nist-traceable voltage calibration
15 summary specifications prt accuracy w/ chub-e4 (includes drift) model range type of cal C200 c 0 c max c dimensions unique selling point 5626-12-x C200?c to 661 c accredited ?0.006 ?0.009 ?0.037 6.35 x 305 mm best reference 5609-12-x C200?c to 670 c order 1930-4-7 ? ?0.010 ?0.011 ?0.054 6.35 x 305 mm highest temperature 5608-12-x C200?c to 500 c order 1930-4-r ? ?0.010 ?0.011 ?0.031 3.2 x 305 mm excellent immersion 5616-12-x C200?c to 420 c traceable ?0.012 ?0.013 ?0.035 6.35 x 298 mm best value 5615-12-x C200?c to 420 c accredited ?0.024 ?0.014 ?0.041 6.35 x 305 mm accredited calibration 5615-9-x C200?c to 420 c accredited ?0.024 ?0.014 ?0.041 4.76 x 229 mm accredited calibration 5615-6-x C200?c to 300 c accredited ?0.024 ?0.014 ?0.041 4.76 x 152 mm smallest 5627a-12 C200 c to 420 c accredited 0.030 0.050 0.125 4.76 x 305 mm most rugged 5627a-9 C200 c to 300 c accredited 0.030 0.050 0.100 4.76 x 229 mm most rugged 5627a-6 C200 c to 300 c accredited 0.030 0.050 0.100 4.76 x 152 mm most rugged thermistor 5610-9-x 0?c to 100 c traceable n/a ?0.009 ?0.023 3.2 x 229 mm high accuracy 5611t-x 0?c to 100 c traceable n/a ?0.009 ?0.023 3 x 6100 mm teflon, flexible x= lead termination. specify a for 9142/9143/9144, d for tweener, l for chub-e4, and i for 1521/1522. accuracy calculated at k=2 95% confidence interval ? calibration ordered separately. for individual probe calibration order the 1923-4-7 or 1923-4-r calibration. each probe includes: ? individual report of calibration ? probe linearization coefficients ? resistance vs. temperature table ? termination to match your thermometer readout (see spec chart) tip: improve the accuracy of your calibration by using an external reference thermometer. calibrated temperature sensors and indicators can improve your results by a factor of 2 or more. recommended accessories: 2601 probe carrying case (for probes up to 12 in long), 2609 probe carrying case with handle (for probes up to 20 in long) www.flukecal.com temperature sensors
16 calibration and metrology training from fluke calibration can help you and your staff become more knowledgeable in a wide variety of dis- ciplines. instructors are experts who work in electrical, temperature, pressure and flow calibration, and who really want to help you learn the foundation and techniques of metrology that you can put to immediate use in your workplace. fluke calibration offers introductory, intermediate, and advanced level courses in a variety of formats to meet your needs. training seminars in american fork, utah www.fukecal.com/tempcal_training get real training from real experts that lays out the basics and builds up to more advanced material for more advanced learners. ? principles of temperature metrology ? advanced topics in temperature metrology ? infrared temperature metrology ? temperature calibration product training service some of the best service and lowest uncertainties are available in our primary and secondary calibration laboratories located in the us and europe. we offer nvlap accredited calibration services in the us and ukas accredited calibration services are available in europe. dont forget to pay a visit to our calibration laboratory when you come for training. fluke calibration po box 9090, everett, wa 98206 u.s.a. fluke europe b.v. po box 1186, 5602 bd eindhoven, the netherlands fluke calibration. precision, performance, confidence. ? for more information call: in the u.s.a. (877) 355-3225 or fax (425) 446-5116 in europe/m-east/africa +31 (0) 40 2675 200 or fax +31 (0) 40 2675 222 in canada (800)-36-fluke or fax (905) 890-6866 training from other countries +1 (425) 446-5500 or fax +1 (425) 446-5116 web access: http://www.flukecal.com ?2011 fluke corporation. specifcations subject to change without notice. printed in u.s.a. 9/2011 3246833b c-en pub. id: 11336-eng, rev 02 modification of this document is not permitted without written permission from fluke corporation.